LODD F2011-18 Captain Dies in Multi-Story Medical Building Fire

Technical BulletinLast updated Monday, June 25, 2012
Add to Library

On July 28, 2011, a 37-year-old career captain died and 9 fire fighters were injured in a 6-story medical building fire while searching for the seat of the fire. At 1228 hours, dispatch sent four companies (2 engines, 1 truck, and a squad company) to an automatic fire alarm at a multistory medical building. Engine 2 reported a working fire with heavy smoke and fire showing on the top floor rear of structure and requested a second alarm. Instead, the dispatch center sent a Division Chief, Battalion Chief, Safety Officer, Engine Company, Rescue company, and Fire Marshal as the complement for a working fire first alarm. Engine 2 fire fighters connected 100 feet of 2½-inch hoseline to the standpipe in the stairwell on the top floor. Engine 2 flowed water for several seconds when their low-air alarms went off and they exited the structure. Rescue 3 took the hoseline but had issues getting water to flow. The top two floors and north stairwell were now heavy with smoke. Ladder 1 was setting up at the A/B corner to access a window on the 6th level (labeled 5th floor), side B. Two of Rescue 3’s members were getting low on air, and the crew moved to the stairwell to exit the building. Two of the members exited the stairwell, but the captain (the victim) went down the hallway and two fire fighters followed him. The low-air alarms of the victim and two fire fighters were sounding when they reached the hallway that was connected to the fire rooms. One of the fire fighters grabbed the victim, who was acting confused, and started back to the stairwell. The other fire fighter got separated in heavy smoke, went toward the fire room, and made it to a window where the platform of Ladder 1 was located just as he ran out of air. The victim ran out of air and told his partner they needed to buddy breath. The victim unclipped his regulator as his partner connected the buddy breather and all the partner’s air escaped through the victim’s SCBA. The victim transmitted a Mayday and activated his PASS (personal alert safety system). The fire fighter also attempted to activate his PASS, called several Maydays prior to removing his mask and began looking for an escape path. At some point, the victim vomited in his facepiece and removed it. The fire fighter crawled down a hallway trying to open several doors unsuccessfully until he found a door he could open to the south stairwell. The fire fighter placed his axe in the door and then returned to the victim. The fire fighter grabbed the victim and pulled him to the south stairwell where he collapsed and the pair fell down a flight of stairs. The victim and the fire fighter were eventually located in the south stairwell by another officer who had exited the north stairwell and heard the victim’s PASS alarm sounding. Medic units transported the victim and the fire fighter to the hospital.

Supplemental Resources

Technical Bulletin

Initial Response to High Rise Fire Alarms

NFA EFO Applied Research Project sought to create a job aid for use in the early phases of high-rise incident assessment by firefighters during the initial assessment

SOG

SOG Sample - Mid-Rise High-Rise Operations

Discusses ops for personnel while at mid rise and high rise fires

Technical Bulletin

Implementation and Effectiveness of Air Management

NFA EFO Applied Research Project established policies requiring firefighters to use air management in accordance with NFPA 1404

Technical Bulletin

Strategies to Improve SCBA Air Management

NFA EFO Applied Research Project identified strategies to improve air management during emergency operations to increase the probability FD staff will exit IDLH atmospheres prior to SCBA low air alarms activation

Technical Bulletin

Alternate Approaches to Individual Air Management

NFA EFO Applied Research Project sought to identify alternatives for complying with NFPA individual air management standards

Technical Bulletin

Declaring a Mayday

VFIS Tailboard Training loss prevention program focuses on the firefighter declaring a mayday as soon as they think they are in danger

Training

Firefighter Safety Calling the Mayday

Discusses proper techniques to call and respond to a mayday

Technical Bulletin

Human Factors Affecting Mayday Decisions

This NFA EFO Applied Research Project seeks to answer whether firefighters will call for help when needed

Technical Bulletin

Incident Command Effectiveness

NFA EFO Applied Research Project intended to identify strategies that will aid the incident commander with the ability to increase their focus and effectiveness at structure fires

Technical Bulletin

Incident Command for High-Rise Occupancies

USFA course provides guidance on deployment techniques for this type occupancy

Technical Bulletin

Improving Incident Command Decision Making

NFA EFO Applied Research Project sought to determine a pathway to improve decision making capabilities of the FDs incident commanders

Training

Command and Control of Incident Operations

USFA on-campus course introducing fire officers to the Incident Command System

Need Help Finding Something?

Our guided search will walk you through all the content available on ResponderHelp, and get you to what you need fast.

Get Started Now

By using our website you agree to our Cookie Policy.